Back to top
Horizontal Laminar Airflow Unit
Horizontal Laminar Airflow Unit

Horizontal Laminar Airflow Unit

Price 45000 INR/ Unit

MOQ : 100 Pieces

Horizontal Laminar Airflow Unit Specification

  • Weight
  • Approximately 80120 kg, depending on size
  • Power
  • 1/4 HP to 1/2 HP Motor
  • Application
  • Laboratories, Pharmaceutical, Electronic Assembly, Hospitals
  • Capacity
  • Variable; typically 600-2000 m/hr depending on model
  • Usage
  • For Providing Clean Air Environment
  • Color
  • White or Stainless Steel Finish
  • Operate Method
  • Manual/Touch Panel/Remote Switch (as per model)
  • Voltage
  • 220-240V AC, 50 Hz
  • Classification
  • Clean Room Equipment
  • Product Type
  • Horizontal Laminar Airflow Unit
  • Material
  • Stainless Steel (SS 304) or Mild Steel Powder Coated
  • Dimension (L*W*H)
  • 1200 x 600 x 600 mm (custom sizes available)
  • Front Cover
  • Transparent acrylic/polycarbonate
  • UV Lamp
  • Built-in UV-C germicidal lamp (optional)
  • Lighting
  • LED/Fluorescent light (15-30W)
  • Control System
  • Microprocessor based/Analog controls
  • Side Panel
  • Acrylic/Glass (clear)
  • Filter Configuration
  • HEPA filter with 99.97% efficiency at 0.3 micron, Pre-filter G4
  • Noise Level
  • < 65 dB(A)
  • Air Velocity
  • 0.3 0.5 m/s (20%) at filter face
  • Vibration Level
  • < 5 microns
  • Number of Blowers
  • 1 (standard), balanced dynamically
  • Work Table
  • Stainless steel work surface
  • Installation Type
  • Table Top / Floor mounted
 

Horizontal Laminar Airflow Unit Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 1 Week
 

About Horizontal Laminar Airflow Unit

Specification

Brand

Dhiraj Trades

Type

Horizontal

Material

SS & Glass

Surface Finish

Polished

Usage/Application

Laboratory

Voltage

220 V

Cabinet Material Grade

SS 206

Country of Origin

Made in India

Dimension

3*2*2 Feet (L*W*H)

 



Advanced Filtration and Airflow Technology

Equipped with a combination of G4 pre-filter and a high-efficiency HEPA filter, this unit provides exceptional contamination control by filtering out particles as small as 0.3 microns. The dynamically balanced blower ensures steady airflow across the entire workspace, maintaining a clean environment essential for sensitive procedures.


Superior Design and Construction

Built with a durable stainless steel or powder-coated mild steel body, the airflow unit promises longevity and easy maintenance. Transparent front covers and side panels offer clear visibility, while the optional UV-C germicidal lamp further enhances protection. Its table-top or floor-mounted installation option fits various workspace requirements.


Flexible and User-Friendly Operation

The laminar airflow unit offers versatile control methods including manual, touch panel, or remote switchadaptable to your precision needs. With LED or fluorescent lighting and vibration control below 5 microns, it ensures both optimal working conditions and user comfort for extended use.

FAQs of Horizontal Laminar Airflow Unit:


Q: How does the horizontal laminar airflow unit maintain a clean air environment?

A: The unit utilizes a G4 pre-filter and a HEPA filter with 99.97% efficiency at 0.3 microns to capture dust, particulate, and microbial contaminants. The airflow is directed horizontally across the workspace at a controlled velocity (0.30.5 m/s), thereby sweeping particulates away from sensitive materials and surfaces.

Q: What is the process for changing or maintaining the filters?

A: For optimal performance, pre-filters should be checked and replaced every 36 months, depending on environmental load, while HEPA filters usually require replacement annually or as indicated by a decrease in airflow efficiency. Always follow manufacturer guidelines and conduct maintenance in a clean environment to prevent contamination.

Q: When should the UV-C germicidal lamp be used, and what are its benefits?

A: The built-in UV-C lamp (optional) is best activated between work sessions to disinfect internal surfaces and prevent microbial growth. Using the UV-C lamp helps ensure a higher level of sterility, especially in applications where contamination control is critical, such as pharmaceutical or medical research.

Q: What types of environments or applications are suitable for this airflow unit?

A: This laminar airflow unit is ideal for laboratories, pharmaceutical manufacturing, electronics assembly, and hospitalssettings that require stringent contamination control. Its efficient filtration and clean airflow support critical processes like media preparation, instrument assembly, and sample handling.

Q: Where can the unit be installed, and what are the available mounting options?

A: The unit supports both table-top and floor-mounted installation to accommodate various workspace layouts. Its compact and customizable sizing allows integration into different laboratory or production room setups across research, healthcare, and industrial facilities.

Q: What types of control systems are available for operating the unit?

A: Depending on the model, you can choose between microprocessor-based digital controls for advanced monitoring, or simple analog controls for straightforward operation. Some models also offer manual switches, touch panels, or remote-control operation to suit your workflow preferences.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number