Ss Fully Automatic Autoclave Specification

  • Dimension (L*W*H)
  • 600 mm x 450 mm x 900 mm (approx)
  • Material
  • Stainless Steel (SS)
  • Operate Method
  • Fully Automatic Digital Control
  • Voltage
  • 220 V AC, 50/60 Hz
  • Usage
  • Sterilizing laboratory and medical equipment
  • Application
  • Hospitals, Laboratories, Research Centers
  • Color
  • Silver
  • Capacity
  • 22-35 liters (options available)
  • Power
  • 2 kW
  • Weight
  • Approx. 60-75 kg
  • Classification
  • Laboratory Sterilization Equipment
  • Product Type
  • Fully Automatic Autoclave
  • Display Type
  • Digital LED Display
  • Safety Features
  • Pressure release valve, automatic cut-off, safety locking lid
  • Door Mechanism
  • Radial locking system with heat resistant gasket
  • Accessories Supplied
  • Sterilizing basket, power cord, instruction manual
  • Temperature Range
  • Up to 134°C
  • Inner Chamber Finish
  • Mirror Polish Stainless Steel
  • Heater Type
  • Immersion type tubular heaters
  • Timer
  • Preset programmable timer, up to 0-120 mins
  • Water Filling
  • Automatic/Manual
  • Pressure Range
  • Up to 2.2 kg/cm² (32 psi)
  • Chamber type
  • Vertical cylindrical
 

Ss Fully Automatic Autoclave Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 1 Week
 

About Ss Fully Automatic Autoclave

Specification

Country of Origin

Made in India

Material

Stainless Steel

Usage

Laboratory

Power Consumption

1.5 KW

Display

Digital

Insulation Wall

Double

Chamber Volume

10 L

Material Grade

SS 206

Automation Grade

Automatic

Shape

Cylindrical

Brand

Dhiraj Traders

 



Advanced Digital Control for Precision Sterilization

This autoclave features a fully automatic digital LED display, allowing you to program cycle times from 0 to 120 minutes. The precise temperature and pressure settings support consistent sterilization, ensuring the safety of laboratory and medical equipment. Its automated controls provide reliability and ease-of-use in high-demand settings.


Superior Safety Features for Secure Operation

Designed with user safety in mind, the SS Fully Automatic Autoclave incorporates a pressure release valve, automatic cut-off system, and a robust safety locking lid. The door is equipped with a radial locking mechanism and a heat-resistant gasket, ensuring secure closure and preventing accidental openings during operation.


Durable Stainless Steel Construction

Manufactured from premium stainless steel with a mirror polish finish, the autoclave's chamber is resistant to corrosion and easy to clean. Its sturdy build, combined with the immersion-type tubular heater and reinforced locking mechanism, makes it suitable for intensive, long-term use in varied environments.

FAQ's of Ss Fully Automatic Autoclave:


Q: How does the SS Fully Automatic Autoclave operate?

A: The autoclave operates using a fully automatic digital control system. Users can program the sterilization cycle duration (up to 120 minutes) and set the desired temperature and pressure. It starts and stops automatically, providing reliable, hands-off sterilization for laboratory or medical equipment.

Q: What safety measures are incorporated in this autoclave?

A: For security, the autoclave features a pressure release valve, automatic cut-off, a safety locking lid with radial locking system, and a heat-resistant gasket to prevent accidental opening or pressure build-up during sterilization.

Q: When should I use automatic versus manual water filling?

A: Automatic water filling is best for routine operations, ensuring constant water levels for optimal performance. Manual filling is helpful during maintenance or when precise water control is required, such as when switching between loads or performing system cleaning.

Q: Where is this autoclave most effectively used?

A: This autoclave is designed for sterilizing equipment in hospitals, laboratories, and research centers. Its versatile capacity options (22-35 liters) and robust safety features make it suitable for high-volume and critical sterilization tasks in professional environments.

Q: What is the process for loading and running a sterilization cycle?

A: Place instruments inside the sterilizing basket, ensuring not to overload. Close the lid securely, select desired cycle parameters on the digital display, and start the cycle. The system will automatically heat, maintain set temperature and pressure, and complete the cycle with programmed timing. A signal indicates when sterilization is finished.

Q: What are the primary benefits of using this autoclave?

A: The SS Fully Automatic Autoclave ensures efficient, consistent sterilization with advanced safety features and digital controls. Its durable construction reduces maintenance needs, while the flexibility of automatic/manual water filling enhances usability for various sterilization scenarios.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Autoclave Category

Portable Laboratory Autoclave

Portable Laboratory Autoclave

Price 25000 INR / Piece

Minimum Order Quantity : 100 Pieces

Color : Silver (Stainless Steel Finish)

Product Type : Portable Laboratory Autoclave

Classification : Class N

Power : 1.5 kW

Vertical Laboratory Autoclave

Vertical Laboratory Autoclave

Price 20000 INR / Piece

Minimum Order Quantity : 1 Piece